OCRO-8042-90
Open Channel Reverse Osmosis Membrane
Different from the traditional spiral wound reverse osmosis membrane, the water flow channel of the open channel reverse osmosis membrane is open, and will not form a tortuous flow channel like the spiral membrane, which greatly reduces the concentration polarization effect and the risk of accumulation of pollutants on the membrane surface;
The open channel design is easier to be fully contacted by the cleaning liquid, so that the inside of the membrane element can be more effectively cleaned, improving the cleaning efficiency;
The open channel design and good water flow conditions can provide higher water flux, thereby improving the processing capacity of the entire system.
| Model | Membrane material | Minimum desalination rate % | Average water production (gpd) | Effective membrane area (ft²) | Design pressure psi(MPa) |
| OCRO-8042-90 | High-density reverse osmosis membrane | 99 | 6,400 | 291 | 1,305psi(9MPa) |
| Test conditions: 32,000ppm NaCl aqueous solution, Pressure 800psi (5.5MPa), Temperature 25℃, pH 7.5, Recovery rate 8%. | |||||
---Description
The flow rate of a single membrane element may be different, but the variation range will not exceed +15%;
The stable desalination rate generally needs to be tested after 24-48 hours of continuous operation, depending on the inlet water quality and operating conditions.
Maximum inlet temperature ································ 40℃
Maximum inlet flow rate ································ 8-12m³/h
Continuous operation pH rangeb ······················ 2-11
Maximum pressure drop of a single membrane ···························· 15psi(0.1MPa)
Maximum inlet SDI15 ····························· 20
Free chlorine tolerance a ······························ <0.1ppm
Short-term cleaning pH range ························· 1-12
a. Under certain conditions, the inlet water contains free chlorine and other oxidants, which will cause serious membrane damage. Oxidative damage is not covered by the product warranty terms;
b. When pH>10, the continuous operation temperature does not exceed 35℃.

| Model | Membrane assembly tie rod length A(mm) | Membrane shell length B(mm) | Inlet/concentrate length C | Membrane assembly outer diameter D(mm) | Inlet/concentrate size(mm) | Water production interface(mm) | Membrane assembly flange surface length E |
| OCRO-8042-90 | 1,350 | 1,200 | 1,420 | φ219 | φ32 | 2*Hose quick connect, interface Φ11.6 |